Sample type: Waste/construction material
Analysis type: Leaching tests
Analysis of substance: Report limit:
Percolation test (column test) L/S 0.1 & 10

Percolation test (10 cm diameter column) according to SIS-CEN/TS 14405

Package info

Price: 11 750 SEK / sample
Std. response time: 8 weeks
Discount group: 1
Sample type: Waste/construction material
Analysis type: Leaching tests
Sample amount: approx. 5 kg
Express: No
Accreditation: Yes
Remarks: A sample is sieved (or crushed) at <4 mm or <10 mm depending on column diameter. The sample is packed and leached while continuously increasing the L/S ratio by slowly pumping in deionized water from the bottom of the column. Maximum 7 leachates are extracted from the column at the L/S ratios 0.1, 0.2, 0.5, 1, 2, 5 and 10. The leachates are analyzed separately. Leachate analyses not included in the price.
For more information about leach testing and analysis of waste.
The TAT can be longer (up to 16 weeks) depending on the properties of the material. Please contact us for more information.